167 research outputs found

    Acoustic Impulse Responses for Wearable Audio Devices

    Full text link
    We present an open-access dataset of over 8000 acoustic impulse from 160 microphones spread across the body and affixed to wearable accessories. The data can be used to evaluate audio capture and array processing systems using wearable devices such as hearing aids, headphones, eyeglasses, jewelry, and clothing. We analyze the acoustic transfer functions of different parts of the body, measure the effects of clothing worn over microphones, compare measurements from a live human subject to those from a mannequin, and simulate the noise-reduction performance of several beamformers. The results suggest that arrays of microphones spread across the body are more effective than those confined to a single device.Comment: To appear at ICASSP 201

    Wedge holography in flat space and celestial holography

    Get PDF
    In this paper, we study codimension two holography in flat spacetimes, based on the idea of the wedge holography. We propose that a region in a d+1 dimensional flat spacetime surrounded by two end of the world branes, which are given by d dimensional hyperbolic spaces, is dual to a conformal field theory (CFT) on a d-1 dimensional sphere. Similarly, we also propose that a d+1 dimensional region in the flat spacetime bounded by two d dimensional de Sitter spaces is holographically dual to a CFT on a d-1 dimensional sphere. Our calculations of the partition function, holographic entanglement entropy and two point functions, support these duality relations and imply that such CFTs are nonunitary. Finally, we glue these two dualities along null surfaces to realize a codimension two holography for a full Minkowski spacetime and discuss a possible connection to the celestial holography

    In Vivo Safety and Persistence of Endoribonuclease Gene-Transduced CD4+ T Cells in Cynomolgus Macaques for HIV-1 Gene Therapy Model

    Get PDF
    BACKGROUND: MazF is an endoribonuclease encoded by Escherichia coli that specifically cleaves the ACA sequence of mRNA. In our previous report, conditional expression of MazF in the HIV-1 LTR rendered CD4+ T lymphocytes resistant to HIV-1 replication. In this study, we examined the in vivo safety and persistence of MazF-transduced cynomolgus macaque CD4+ T cells infused into autologous monkeys. METHODOLOGY/PRINCIPAL FINDINGS: The in vivo persistence of the gene-modified CD4+ T cells in the peripheral blood was monitored for more than half a year using quantitative real-time PCR and flow cytometry, followed by experimental autopsy in order to examine the safety and distribution pattern of the infused cells in several organs. Although the levels of the MazF-transduced CD4+ T cells gradually decreased in the peripheral blood, they were clearly detected throughout the experimental period. Moreover, the infused cells were detected in the distal lymphoid tissues, such as several lymph nodes and the spleen. Histopathological analyses of tissues revealed that there were no lesions related to the infused gene modified cells. Antibodies against MazF were not detected. These data suggest the safety and the low immunogenicity of MazF-transduced CD4+ T cells. Finally, gene modified cells harvested from the monkey more than half a year post-infusion suppressed the replication of SHIV 89.6P. CONCLUSIONS/SIGNIFICANCE: The long-term persistence, safety and continuous HIV replication resistance of the mazF gene-modified CD4+ T cells in the non-human primate model suggests that autologous transplantation of mazF gene-modified cells is an attractive strategy for HIV gene therapy

    Molecular basis for the dosing time-dependency of anti-allodynic effects of gabapentin in a mouse model of neuropathic pain

    Get PDF
    <p>Abstract</p> <p>Background</p> <p>Neuropathic pain is characterized by hypersensitivity to innocuous stimuli (tactile allodynia) that is nearly always resistant to NSAIDs or even opioids. Gabapentin, a GABA analogue, was originally developed to treat epilepsy. Accumulating clinical evidence supports the effectiveness of this drug for diverse neuropathic pain. In this study, we showed that the anti-allodynic effect of gabapentin was changed by the circadian oscillation in the expression of its target molecule, the calcium channel α2δ-1 subunit.</p> <p>Results</p> <p>Mice were underwent partial sciatic nerve ligation (PSL) to create a model of neuropathic pain. The paw withdrawal threshold (PWT) in PSL mice significantly decreased and fluctuated with a period length about 24 h. The PWT in PSL mice was dose-dependently increased by intraperitoneal injection of gabapentin, but the anti-allodynic effects varied according to its dosing time. The protein levels of α2δ-1 subunit were up-regulated in the DRG of PSL mice, but the protein levels oscillated in a circadian time-dependent manner. The time-dependent oscillation of α2δ-1 subunit protein correlated with fluctuations in the maximal binding capacity of gabapentin. The anti-allodynic effect of gabapentin was attenuated at the times of the day when α2δ-1 subunit protein was abundant.</p> <p>Conclusions</p> <p>These findings suggest that the dosing time-dependent difference in the anti-allodynic effects of gabapentin is attributable to the circadian oscillation of α2δ-1 subunit expression in the DRG and indicate that the optimizing its dosing schedule helps to achieve rational pharmacotherapy for neuropathic pain.</p

    Generation of Tetrafluoroethylene–Propylene Elastomer-Based Microfluidic Devices for Drug Toxicity and Metabolism Studies

    Get PDF
    フッ素系エラストマー素材を用いた肝臓チップの開発と薬物代謝・毒性試験への応用. 京都大学プレスリリース. 2021-09-16.Drug testing on miniatured livers. 京都大学プレスリリース. 2021-09-17.Polydimethylsiloxane (PDMS) is widely used to fabricate microfluidic organs-on-chips. Using these devices (PDMS-based devices), the mechanical microenvironment of living tissues, such as pulmonary respiration and intestinal peristalsis, can be reproduced in vitro. However, the use of PDMS-based devices in drug discovery research is limited because of their extensive absorption of drugs. In this study, we investigated the feasibility of the tetrafluoroethylene–propylene (FEPM) elastomer to fabricate a hepatocyte-on-a-chip (FEPM-based hepatocyte chip) with lower drug absorption. The FEPM-based hepatocyte chip expressed drug-metabolizing enzymes, drug-conjugating enzymes, and drug transporters. Also, it could produce human albumin. Although the metabolites of midazolam and bufuralol were hardly detected in the PDMS-based hepatocyte chip, they were detected abundantly in the FEPM-based hepatocyte chip. Finally, coumarin-induced hepatocyte cytotoxicity was less severe in the PDMS-based hepatocyte chip than in the FEPM-based hepatocyte chip, reflecting the different drug absorptions of the two chips. In conclusion, the FEPM-based hepatocyte chip could be a useful tool in drug discovery research, including drug metabolism and toxicity studies

    Health Checkup and Telemedical Intervention Program for Preventive Medicine in Developing Countries: Verification Study

    Get PDF
    Background: The prevalence of non-communicable diseases is increasing throughout the world, including developing countries. / Objective: The intent was to conduct a study of a preventive medical service in a developing country, combining eHealth checkups and teleconsultation as well as assess stratification rules and the short-term effects of intervention. / Methods: We developed an eHealth system that comprises a set of sensor devices in an attaché case, a data transmission system linked to a mobile network, and a data management application. We provided eHealth checkups for the populations of five villages and the employees of five factories/offices in Bangladesh. Individual health condition was automatically categorized into four grades based on international diagnostic standards: green (healthy), yellow (caution), orange (affected), and red (emergent). We provided teleconsultation for orange- and red-grade subjects and we provided teleprescription for these subjects as required. / Results: The first checkup was provided to 16,741 subjects. After one year, 2361 subjects participated in the second checkup and the systolic blood pressure of these subjects was significantly decreased from an average of 121 mmHg to an average of 116 mmHg (P<.001). Based on these results, we propose a cost-effective method using a machine learning technique (random forest method) using the medical interview, subject profiles, and checkup results as predictor to avoid costly measurements of blood sugar, to ensure sustainability of the program in developing countries. / Conclusions: The results of this study demonstrate the benefits of an eHealth checkup and teleconsultation program as an effective health care system in developing countries
    corecore